1. Scope
1.1 This test method covers the titrimetric determination of vanadium in liquid vanadium driers and utilizes the disodium salt of ethylenediaminetetraacetic acid dihydrate (EDTA).
1.2 This test method is limited to the determination of the vanadium content of a liquid vanadium drier that does not contain other drier elements. This test method is not applicable to drier blends.
1.3 All cations that can be titrated with EDTA in alkaline media interfere and must not be present in the sample.
1.4 This test method has been tested for concentrations of 3 and 4% vanadium, but there is no reason to believe that it is not suitable for higher or lower vanadium concentrations provided specimen size is adjusted proportionately.
1.5 This standard does not purport to address the safety problems associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.
ASTM Standards
D600 Specification for Liquid Paint Driers
D1193 Specification for Reagent Water
E180 Practice for Determining the Precision of ASTM Methods for Analysis and Testing of Industrial and Specialty Chemicals
E300 Practice for Sampling Industrial Chemicals
Keywords
EDTA-analysis; liquid drier; paint driers; vanadium drier; EDTA method; Vanadium content; Paint driers;
ICS Code
ICS Number Code 87.060.99 (Other paint ingredients)