Abstract
This specification covers the design and dimensional requirements for reusable glass Westergren tubes that measure the erythrocyte sedimentation rate (ESR), which is the suspension stability,
or amount of settling after a specified time, of red blood cells in diluted, anti-coagulated human blood. The tubes shall be fabricated from Type I, Class B borosilicate glass, or Type II
soda lime glass. Tubes shall comply with requirements for graduation line length and numbering, marking permanency, grinding bevel, and workmanship. The tubes should also pass a pigmentation
and amber stain test.
This abstract is a brief summary of the referenced standard. It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for
its use and application. ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date.
1. Scope
1.1 This specification describes requirements for a tube that measures the erythrocyte sedimentation rate (ESR). ESR is the suspension stability of red cells in diluted, anti-coagulated human
blood.
1.1.1 The use of the term rate is, strictly speaking, not correct. The test measures the amount of settling of red cells after a specified time.
1.2 The tubes are used together with a special rack to ensure they remain in a vertical position during the test.
1.3 This specification includes many dimensional requirements that are, for the most part, in agreement with the British Standards Institution, German Standards Institute, International
Committee for Standardization in Haematology, and the National Committee for Clinical Laboratory Standards publications on Westergren tubes. The clinical procedure using the tube described in
this specification is known as the Westergren Method.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of
this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.
ASTM Standards
E438 Specification for Glasses in Laboratory Apparatus
E920 Specification for Commercially Packaged Laboratory Apparatus
E921 Specification for Export Packaged Laboratory Apparatus
E1133 Practice for Performance Testing of Packaged Laboratory Apparatus for United States Government Procurements
E1157 Specification for Sampling and Testing of Reusable Laboratory Glassware
Keywords
blood; glass; reusable; sedimentation rate; westergren; ESR (erythrocyte sedimentation rate); Hematology; Laboratory apparatus--specifications; Sediment; Westergren method ;
ICS Code
ICS Number Code 11.100 (Laboratory medicine)
DOI: 10.1520/E0923-97R08