Cart (0)
  • No items in cart.
Total
$0
There is a technical issue about last added item. You can click "Report to us" button to let us know and we resolve the issue and return back to you or you can continue without last item via click to continue button.
Search book title
Enter keywords for book title search
Search book content
Enter keywords for book content search
Filters:
FORMAT
BOOKS
PACKAGES
EDITION
to
PUBLISHER
(1)
(326)
(573)
(44)
(234)
(969)
(652)
(2114)
(64)
(92448)
(54)
(541)
(117)
(33)
(21)
(20)
(93277)
(3)
(17)
(1)
(351)
(300)
(6217)
(240)
(16)
(5)
(1635)
(16)
(19)
(28)
(4)
 
(6)
(7)
(115)
(3)
(57)
(5)
(5)
(1)
(1)
(2)
(25)
(26)
(27)
(13)
(61)
(24)
(22)
(7)
(8)
(20)
(1)
(3)
(50)
(6)
(31)
CONTENT TYPE
 Act
 Admin Code
 Announcements
 Bill
 Book
 CADD File
 CAN
 CEU
 Charter
 Checklist
 City Code
 Code
 Commentary
 Comprehensive Plan
 Conference Paper
 County Code
 Course
 DHS Documents
 Document
 Errata
 Executive Regulation
 Federal Guideline
 Firm Content
 Guideline
 Handbook
 Interpretation
 Journal
 Land Use and Development
 Law
 Legislative Rule
 Local Amendment
 Local Code
 Local Document
 Local Regulation
 Local Standards
 Manual
 Model Code
 Model Standard
 Notice
 Ordinance
 Other
 Paperback
 PASS
 Periodicals
 PIN
 Plan
 Policy
 Product
 Product - Data Sheet
 Program
 Provisions
 Requirements
 Revisions
 Rules & Regulations
 Standards
 State Amendment
 State Code
 State Manual
 State Plan
 State Standards
 Statute
 Study Guide
 Supplement
 Sustainability
 Technical Bulletin
 All
  • BSI
    BS 5975:2019 Code of practice for temporary works procedures and the permissible stress design of falsework
    Edition: 2019
    $641.56
    / user per year

Description of BS 5975:2019 2019

This British Standard gives recommendations and guidance on the procedural controls to be applied to all aspects of temporary works in the construction industry. It also includes guidance on design, specification, construction, use and dismantling of falsework. This standard gives guidance on permissible stress design of all falsework. The guidance also applies to the design of class A falsework1 defined in BS EN 12812, the design of which is specifically excluded from BS EN 12812.

Section 1 gives recommendations in relation to training and education.

Section 2 gives recommendations for procedures to ensure that temporary works are conceived, designed, specified, constructed, used and dismantled all in a safe and controlled manner suitable for all construction projects. These procedures include clauses relating to all roles involved in temporary works: clients, permanent works designers, temporary works designers, contractors (including construction management organizations), suppliers and manufacturers.

Construction sites and methods adopted for controlling the temporary works vary. This British Standard recognizes that the extent of control measures required are greater on the larger or more complex projects, as can be encountered on major infrastructure projects, power stations, airports etc. Generally procedures are to be in accordance with this standard but additional client specific procedures might be required on major infrastructure projects.

Section 3 covers the design of temporary works and in particular the design of falsework and relevant formwork. In addition Section 3 covers: materials including material factors; loads and load factors; design of falsework, including both proprietary equipment and traditional scaffolding solutions; wind loading (reference to temporary and permanent stability) and reference to other British Standards for the design of structural steelwork, reinforced concrete and excavation support. Although Section 3 was written for permissible stress design, the design concepts and the service loads stated are applicable to limit state design. The loads, including wind loads, are the unfactored service loads and conform to both BS EN 1991‑1‑4 and BS EN 12812.

The structural design element in this British Standard is additional information necessary for the structural design of falsework. It can be used in conjunction with existing structural standards.

BS EN 12812 states that design class A is only to be adopted where:

 a) slabs have a cross-sectional area not exceeding 0.3 m2 per metre width of slab;

 b) beams have a cross-sectional area not exceeding 0.5 m2;

 c) the clear span of beams and slabs does not exceed 6.0 m;

 d) the height to the underside of the permanent structure does not exceed 3.5 m.