Cart (0)
  • No items in cart.
Total
$0
There is a technical issue about last added item. You can click "Report to us" button to let us know and we resolve the issue and return back to you or you can continue without last item via click to continue button.
Search book title
Enter keywords for book title search
Search book content
Enter keywords for book content search
Filters:
FORMAT
BOOKS
PACKAGES
EDITION
to
PUBLISHER
(1)
(326)
(573)
(44)
(234)
(969)
(652)
(2114)
(64)
(92448)
(54)
(541)
(117)
(33)
(20)
(19)
(93277)
(3)
(17)
(1)
(351)
(300)
(6217)
(240)
(16)
(5)
(1621)
(16)
(19)
(28)
(4)
 
(6)
(7)
(115)
(3)
(57)
(5)
(5)
(1)
(1)
(2)
(25)
(26)
(27)
(13)
(61)
(24)
(22)
(7)
(8)
(20)
(1)
(3)
(50)
(6)
(31)
CONTENT TYPE
 Act
 Admin Code
 Announcements
 Bill
 Book
 CADD File
 CAN
 CEU
 Charter
 Checklist
 City Code
 Code
 Commentary
 Comprehensive Plan
 Conference Paper
 County Code
 Course
 DHS Documents
 Document
 Errata
 Executive Regulation
 Federal Guideline
 Firm Content
 Guideline
 Handbook
 Interpretation
 Journal
 Land Use and Development
 Law
 Legislative Rule
 Local Amendment
 Local Code
 Local Document
 Local Regulation
 Local Standards
 Manual
 Model Code
 Model Standard
 Notice
 Ordinance
 Other
 Paperback
 PASS
 Periodicals
 PIN
 Plan
 Policy
 Product
 Program
 Provisions
 Requirements
 Revisions
 Rules & Regulations
 Standards
 State Amendment
 State Code
 State Manual
 State Plan
 State Standards
 Statute
 Study Guide
 Supplement
 Technical Bulletin
 All
  • BSI
    BS EN 16612:2019 Glass in building. Determination of the lateral load resistance of glass panes by calculation
    Edition: 2019
    $497.46
    / user per year

Description of BS EN 16612:2019 2019

This document gives a method of determining the design value of the bending strength of glass. It gives the general method of calculation, and guidance for lateral load resistance of linearly supported glazed elements used as infill panels.

NOTE

Examples of lateral loads are wind loads, snow loads, self weight of sloping glass, and cavity pressure variations on insulating glass units.

This document gives recommended values for the following factors for glass as a material:

— material partial factors, ? M;A and ? M;v ;

— factors for the load duration, kmod ;

— factor for stressed edges, ke.

Most glass in buildings is used as infill panels. This document covers those infill panels that are in a class of consequence lower than those covered in EN 1990, so proposed values for the partial load factors, ?Q and ?G, are given for these infill panels.

The action of cavity pressure variations on insulating glass units is not covered by Eurocodes, so this document also gives proposed values of combination factors, ?0, ?1 and ?2, for this action.

This document does not determine suitability for purpose. Resistance to lateral loads is only one part of the design process, which could also need to take into account:

  • in-plane loading, buckling, lateral torsional buckling, and shear forces,

  • environmental factors (e.g. sound insulation, thermal properties),

  • safety characteristics (e.g. fire performance, mode of breakage in relation to human safety, security).

This document does not apply to channel shaped glass, glass blocks and pavers, or vacuum insulated glass units.



About BSI

BSI Group, also known as the British Standards Institution is the national standards body of the United Kingdom. BSI produces technical standards on a wide range of products and services and also supplies certification and standards-related services to businesses.

X