Cart (0)
  • No items in cart.
Total
$0
There is a technical issue about last added item. You can click "Report to us" button to let us know and we resolve the issue and return back to you or you can continue without last item via click to continue button.
Search book title
Enter keywords for book title search
Search book content
Enter keywords for book content search
Filters:
FORMAT
BOOKS
PACKAGES
EDITION
to
PUBLISHER
(1)
(326)
(573)
(44)
(234)
(969)
(652)
(2114)
(64)
(92448)
(54)
(541)
(117)
(33)
(21)
(20)
(93277)
(3)
(17)
(1)
(351)
(300)
(6217)
(240)
(16)
(5)
(1635)
(16)
(19)
(28)
(4)
 
(6)
(7)
(115)
(3)
(57)
(5)
(5)
(1)
(1)
(2)
(25)
(26)
(27)
(13)
(61)
(24)
(22)
(7)
(8)
(20)
(1)
(3)
(50)
(6)
(31)
CONTENT TYPE
 Act
 Admin Code
 Announcements
 Bill
 Book
 CADD File
 CAN
 CEU
 Charter
 Checklist
 City Code
 Code
 Commentary
 Comprehensive Plan
 Conference Paper
 County Code
 Course
 DHS Documents
 Document
 Errata
 Executive Regulation
 Federal Guideline
 Firm Content
 Guideline
 Handbook
 Interpretation
 Journal
 Land Use and Development
 Law
 Legislative Rule
 Local Amendment
 Local Code
 Local Document
 Local Regulation
 Local Standards
 Manual
 Model Code
 Model Standard
 Notice
 Ordinance
 Other
 Paperback
 PASS
 Periodicals
 PIN
 Plan
 Policy
 Product
 Product - Data Sheet
 Program
 Provisions
 Requirements
 Revisions
 Rules & Regulations
 Standards
 State Amendment
 State Code
 State Manual
 State Plan
 State Standards
 Statute
 Study Guide
 Supplement
 Sustainability
 Technical Bulletin
 All
  • BSI
    BS EN 61340-4-4:2012+A1:2015 Electrostatics - Standard test methods for specific applications. Electrostatic classification of flexible intermediate bulk containers (FIBC)
    Edition: 2015
    $473.45
    / user per year

Description of BS EN 61340-4-4:2012+A1:2015 2015

This part of IEC 61340 specifies requirements for flexible intermediate bulk containers (FIBC) between 0,25 m 3 and 3 m 3 in volume, intended for use in hazardous explosive atmospheres. The explosive atmosphere may be created by the contents in the FIBC or may exist outside the FIBC.

The requirements include:

  • classification and labelling of FIBC;

  • classification of inner liners;

  • specification of test methods for each type of FIBC and inner liner;

  • design and performance requirements for FIBC and inner liners;

  • safe use of FIBC (including those with inner liners) within different zones defined for explosion endangered environments, described for areas where combustible dusts are, or may be, present ( IEC 60079‑10‑2 ), and for explosive gas atmospheres ( IEC 60079‑10‑1 );

  • procedures for type qualification and certification of FIBC, including the safe use of inner liners.

NOTE 1

Guidance on test methods that may be used for manufacturing quality control is given in Annex C.

The requirements of this standard are applicable to all types of FIBC and inner liners, tested as manufactured, prior to use and intended for use in hazardous explosive atmospheres: Zones 1 and 2 (Groups IIA and IIB only) and Zones 21 and 22 (see Annex D for classification of hazardous areas and explosion groups). For some types of FIBC, the requirements of this standard apply only to use in hazardous explosive atmospheres with minimum ignition energy of 0,14 mJ or greater and where charging currents do not exceed 3,0 µA.

NOTE 2

0,14 mJ is the minimum ignition energy of a typical Group IIB gas or vapour. Although more sensitive materials exist, 0,14 mJ is the lowest minimum ignition energy of any material that is likely to be present when FIBC are emptied. 3,0 µA is the highest charging current likely to be found in common industrial processes. This combination of minimum ignition energy and charging current represents the most severe conditions that might be expected in practice.

Compliance with the requirements specified in this standard does not necessarily ensure that hazardous electrostatic discharges, e.g. cone discharges, will not be generated by the contents in FIBC. Information on the risks associated with cone discharges is given in Annex E.

Compliance with the requirements of this standard does not mitigate the need for full risk assessment. For example, metal and other conductive powders and toner powders may require additional precautions to prevent hazardous discharges from the powders.

NOTE 3

In the examples mentioned in the paragraph above, additional precautions may be necessary in the case of metal or other conductive powder because if the powder is isolated and becomes charged, incendiary sparks may occur, and in the case of toner powders, incendiary discharges may occur during rapid filling and emptying operations. IEC/TS TS 60079‑32‑1 [1] 1 gives guidance on additional precautions that may be necessary.

Test methods included in this standard may be used in association with other performance requirements, for example when a risk assessment has shown the minimum ignition energy of concern is less than 0,14 mJ, charging currents are greater than 3,0 µA, or the ambient conditions are outside of the range specified in this standard.

Compliance with the requirements specified in this standard does not necessarily ensure that electric shocks to personnel will not occur from FIBC during normal use.



About BSI

BSI Group, also known as the British Standards Institution is the national standards body of the United Kingdom. BSI produces technical standards on a wide range of products and services and also supplies certification and standards-related services to businesses.

X